Why did my Cloning fail?
Transformation plate shows no colonies (or far below expected CFU). Colonies grow but screened clones lack the insert (vector only). Screened clones contain an insert of unexpected size or sequence. Tiny satellite colonies surround larger colonies on antibiotic plates. Colonies appear but CFU is far below the
Playbooks
- Cloning: no coloniesTransformation plate shows no colonies (or far below expected CFU).
- Cloning: empty vectorColonies grow but screened clones lack the insert (vector only).
- Cloning: wrong insertScreened clones contain an insert of unexpected size or sequence.
- Cloning: satellite coloniesTiny satellite colonies surround larger colonies on antibiotic plates.
- Cloning: low transformation efficiencyColonies appear but CFU is far below the competent-cell rating or lab baseline.
Calculators
FAQ — Cloning
- No colonies
- Transformation plate shows no colonies (or far below expected CFU). Transform a known-good plasmid on the same competent cells and plate batch — Controls-first split between cells/plates vs ligation chemistry. Pour fresh antibiotic plates at the validated concentration; check expiry — Over-strong or degraded antibiotic is a classic zero-colony cause. Re-ligate with a fresh insert:vector ratio and include a no-insert control — Confirms assembly chemistry before changing transformation parameters. Use standard heat-shock (42 °C / 30–45 s) and SOC recovery 1 h at 37 °C — Recovers many protocol-drift failures.
- Empty vector
- Colonies grow but screened clones lack the insert (vector only). Re-digest vector longer; gel-purify linear band; phosphatase-treat sticky ends — Cuts the uncut/re-ligation background that floods empty clones. Re-prep insert; confirm concentration and size before ligation — Invisible/degraded insert presents as all-empty screens. Set insert:vector ≈ 3:1 molar and include a no-insert control plate — Ratio and control plate quantify how much empty background to expect.
- Wrong insert
- Screened clones contain an insert of unexpected size or sequence. Re-amplify insert; verify size on gel against ladder before ligation — Stops wrong-band excision from propagating into clones. Confirm oligo IDs/sequences against the design file; re-order if mismatched — Oligo mix-ups look like successful cloning of the wrong thing. Sequence 2–3 colonies across the junctions before scaling minipreps — Catch wrong inserts before investing in midiprep/expression.
- Satellite colonies
- Tiny satellite colonies surround larger colonies on antibiotic plates. Pour fresh plates at the validated antibiotic concentration; store cold and use promptly — Degraded antibiotic is the usual satellite driver. Pick large colonies early; avoid incubating amp plates overnight-plus — Limits local antibiotic breakdown around true transformants. Dilute transformation before plating to reduce CFU density — Fewer true colonies means less secreted β-lactamase rescue.
- Low transformation efficiency
- Colonies appear but CFU is far below the competent-cell rating or lab baseline. Thaw a fresh competent-cell aliquot on ice; avoid re-freezing — Partial competence loss is the top efficiency drop cause. Use ≤10% ligation volume in the transformation or purify DNA first — Excess salts/enzymes suppress competence. Standardise heat-shock to 42 °C / 45 s with SOC recovery 1 h — Recovers many protocol-drift efficiency losses.