Cloning: no colonies

Transformation plate shows no colonies (or far below expected CFU).

  1. Ranked causes

    1. Antibiotic plate wrong, expired, or too concentratedPositive-control plasmid also yields zero CFU on the same plate batch.
    2. Competent cells inactive (storage, thaw, or wrong strain)Same ligation succeeds in a fresh competent-cell aliquot.
    3. Ligation / assembly failed (ratios, insert:vector ratio, time)Uncut vector control gives colonies; ligation mix does not.
    4. Heat-shock / electroporation conditions offPositive-control DNA fails on this protocol but works with standard heat-shock timing.
    5. Recovery media / incubation temperature wrong after transformationSkipping 37 °C recovery or using antibiotic too early kills transformants.
  2. Recovery steps

    1. Transform a known-good plasmid on the same competent cells and plate batchControls-first split between cells/plates vs ligation chemistry.
    2. Pour fresh antibiotic plates at the validated concentration; check expiryOver-strong or degraded antibiotic is a classic zero-colony cause.
    3. Re-ligate with a fresh insert:vector ratio and include a no-insert controlConfirms assembly chemistry before changing transformation parameters.
    4. Use standard heat-shock (42 °C / 30–45 s) and SOC recovery 1 h at 37 °CRecovers many protocol-drift failures.
  3. Controls first

    • Did the positive-control plasmid yield colonies on the same cells and antibiotic plates?If no: Cells, plates, or transformation conditions — not the ligation alone.
    • Did the positive-control plasmid yield colonies on the same cells and antibiotic plates?If yes: Ligation/assembly or insert quality — keep cells/plates as working controls.

Diagnose your run

Opens Diagnostics capture with this first-party playbook behind it. Sign in if the workspace asks.